VERSION 34
@!
@! Stage 5 Project Data Update Package for Project [#] - Energization [#]
@! ========================
@! RAW AND SEQUENCE DATA 
@! Created by [Engineer’s Name] at [Company Name] for [Client Name if consultant] on [Date]
@!
BAT_PURGBRN,123,456,'10'
RDCH
1
0 / END OF SYSTEM-WIDE DATA, BEGIN BUS DATA
@!   I,'NAME', BASKV, IDE,AREA,ZONE,OWNER, VM,        VA,    NVHI,   NVLO,   EVHI,   EVLO
1111,'BUS1', 138.0000,1,   4,   1,  12,1.00871,  27.3496,1.10000,0.90000,1.10000,0.90000
2222,'BUS2', 138.0000,1,   4,   1,  12,1.00743,  27.1717,1.10000,0.90000,1.10000,0.90000
3333,'BUS3',  69.0000,1,   4,   1,  12,1.01330,  28.3619,1.10000,0.90000,1.10000,0.90000
123,'BUS4',  69.0000,1,   4,   1,  12,1.01330,  28.3619,1.10000,0.90000,1.10000,0.90000
0 / END OF BUS DATA, BEGIN LOAD DATA
0 / END OF LOAD DATA, BEGIN FIXED SHUNT DATA
0 / END OF FIXED SHUNT DATA, BEGIN GENERATOR DATA
0 / END OF GENERATOR DATA, BEGIN BRANCH DATA
@!   I,     J,'CKT',     R,          X,         B,    'N A M E', RATE1,   RATE2,   RATE3,   RATE4,   RATE5,   RATE6,   RATE7,   RATE8,   RATE9,  RATE10,  RATE11,  RATE12,    GI,       BI,       GJ,       BJ,STAT,MET,  LEN,  O1,  F1,    O2,  F2,    O3,  F3,    O4,  F4
   123,3333,'01', 5.31340E-4, 4.47300E-3,   0.00012,'BRANCH1',  150.00,  163.00,  150.00,  163.00,    0.00,    0.00,    0.00,    0.00,    0.00,    0.00,    0.00,    0.00,  0.00000,  0.00000,  0.00000,  0.00000,1,2,   0.56,  12,1.0000
1111,2222,'02', 2.52048E-3, 1.55272E-2,   0.00445,'BRANCH2',  196.00,  215.00,  196.00,  215.00,    0.00,    0.00,    0.00,    0.00,    0.00,    0.00,    0.00,    0.00,  0.00000,  0.00000,  0.00000,  0.00000,1,2,   7.00,  12,1.0000
0 / END OF BRANCH DATA, BEGIN SYSTEM SWITCHING DEVICE DATA
0 / END OF SYSTEM SWITCHING DEVICE DATA, BEGIN TRANSFORMER DATA
@!   I,     J,     K,'CKT',CW,CZ,CM,    MAG1,       MAG2,NMETR,               'N A M E',               STAT,O1,  F1,    O2,  F2,    O3,  F3,    O4,  F4,     'VECGRP', ZCOD
@!   R1-2,       X1-2,   SBASE1-2,     R2-3,       X2-3,   SBASE2-3,     R3-1,       X3-1,   SBASE3-1, VMSTAR,   ANSTAR
@!WINDV1,  NOMV1,    ANG1,  RATE1-1,  RATE1-2,  RATE1-3,  RATE1-4,  RATE1-5,  RATE1-6,  RATE1-7,  RATE1-8,  RATE1-9, RATE1-10, RATE1-11, RATE1-12,COD1,CONT1,   RMA1,    RMI1,    VMA1,    VMI1, NTP1,TAB1,  CR1,     CX1,   CNXA1
@!WINDV2,  NOMV2,    ANG2,  RATE2-1,  RATE2-2,  RATE2-3,  RATE2-4,  RATE2-5,  RATE2-6,  RATE2-7,  RATE2-8,  RATE2-9, RATE2-10, RATE2-11, RATE2-12,COD2,CONT2,   RMA2,    RMI2,    VMA2,    VMI2, NTP2,TAB2,  CR2,     CX2,   CNXA2
@!WINDV3,  NOMV3,    ANG3,  RATE3-1,  RATE3-2,  RATE3-3,  RATE3-4,  RATE3-5,  RATE3-6,  RATE3-7,  RATE3-8,  RATE3-9, RATE3-10, RATE3-11, RATE3-12,COD3,CONT3,   RMA3,    RMI3,    VMA3,    VMI3, NTP3,TAB3,  CR3,     CX3,   CNXA3
2222,   456,     0,'T1', 1, 1, 1, 3.40000E-4,-3.20000E-4,1,'TRANSFORMER1',1,  12,1.0000,   0,1.0000,   0,1.0000,   0,1.0000,'YNa0        '
 1.74000E-3, 8.57200E-2,   100.00
1.00000,   0.000,   0.000,   50.00,   60.00,   70.00,   80.00,   90.00,   100.00,     0.00,     0.00,     0.00,     0.00,     0.00,     0.00,-1,    456, 1.10000, 0.90000, 1.10000, 0.90000,  33, 0, 0.00000, 0.00000,  0.000
1.00000,   0.000
1111,3333,     0,'T2', 1, 1, 1, 3.30000E-4,-3.40000E-4,2,'TRANSFORMER2',1,  12,1.0000,   0,1.0000,   0,1.0000,   0,1.0000,'YNyn0       '
 1.75000E-3, 8.57200E-2,   100.00
1.00000,   0.000,   0.000,   50.00,   60.00,   70.00,   80.00,   90.00,   100.00,     0.00,     0.00,     0.00,     0.00,     0.00,     0.00,-1, 3333, 1.10000, 0.90000, 1.10000, 0.90000,  33, 0, 0.00000, 0.00000,  0.000
1.00000,   0.000
0 / END OF TRANSFORMER DATA, BEGIN AREA DATA
0 / END OF AREA DATA, BEGIN TWO-TERMINAL DC DATA
0 / END OF TWO-TERMINAL DC DATA, BEGIN VSC DC LINE DATA
0 / END OF VSC DC LINE DATA, BEGIN IMPEDANCE CORRECTION DATA
0 / END OF IMPEDANCE CORRECTION DATA, BEGIN MULTI-TERMINAL DC DATA
0 / END OF MULTI-TERMINAL DC DATA, BEGIN MULTI-SECTION LINE DATA
0 / END OF MULTI-SECTION LINE DATA, BEGIN ZONE DATA
0 / END OF ZONE DATA, BEGIN INTER-AREA TRANSFER DATA
0 / END OF INTER-AREA TRANSFER DATA, BEGIN OWNER DATA
0 / END OF OWNER DATA, BEGIN FACTS DEVICE DATA
0 / END OF FACTS DEVICE DATA, BEGIN SWITCHED SHUNT DATA
0 / END OF SWITCHED SHUNT DATA, BEGIN GNE DATA
0 / END OF GNE DATA, BEGIN INDUCTION MACHINE DATA
0 / END OF INDUCTION MACHINE DATA, BEGIN SUBSTATION DATA
0 / END OF SUBSTATION DATA
Q
RESQ
1
1, 34
0 / END OF SYSTEM-WIDE DATA, BEGIN GENERATOR DATA
0  / END OF GENERATOR DATA, BEGIN LOAD DATA
0  / END OF LOAD DATA, BEGIN ZERO SEQ. NON-TRANSFORMER BRANCH DATA
@!!  I,     J,'ICKT',    RLINZ,      XLINZ,       BCHZ,         GI,         BI,         GJ,         BJ,        IPR,SCTYP
	123,3333,'01', 4.64100E-3, 1.56040E-2,    0.00005, 0.00000E+0, 0.00000E+0, 0.00000E+0, 0.00000E+0, 0.00000E+0,0
	1111,2222,'02', 8.22306E-3, 4.26644E-2,    0.00236, 0.00000E+0, 0.00000E+0, 0.00000E+0, 0.00000E+0, 0.00000E+0,0
0  / END OF ZERO SEQ. NON-TRANSFORMER BRANCH DATA, BEGIN ZERO SEQ. MUTUAL DATA
0  / END OF ZERO SEQ. MUTUAL DATA, BEGIN ZERO SEQ. TRANSFORMER DATA
@!!  I,     J,     K,'ICKT',CZ0,CZG,CC,   RG1,        XG1,        R01,        X01,        RG2,        XG2,        R02,        X02,     RNUTRL,     XNUTRL
@!!  I,     J,     K,'ICKT',CZ0,CZG,CC,   RG1,        XG1,        R01,        X01,        RG2,        XG2,        R02,        X02,        RG3,        XG3,        R03,        X03,     RNUTRL,     XNUTRL
2222,   456,     0,'T1',1,1,  8, 6.34780E-1, 1.45233E+0, 1.75000E-3, 8.13300E-2,-4.61246E+0,-3.79880E+0, 0.00000E+0, 0.00000E+0, 0.00000E+0, 0.00000E+0
3333,1111,     0,'T2',1,1,  8, 6.42670E-1, 1.41496E+0, 1.82000E-3, 8.12200E-2,-4.35908E+0,-3.48880E+0, 0.00000E+0, 0.00000E+0, 0.00000E+0, 0.00000E+0
0  / END OF ZERO SEQ. TRANSFORMER DATA, BEGIN ZERO SEQ. SWITCHED SHUNT DATA
0  / END OF ZERO SEQ. SWITCHED SHUNT DATA, BEGIN ZERO SEQ. FIXED SHUNT DATA
0  / END OF ZERO SEQ. FIXED SHUNT DATA, BEGIN INDUCTION MACHINE DATA
0  / END OF INDUCTION MACHINE DATA, BEGIN NON CONVENTIONAL SOURCE FAULT CONTRIBUTION DATA
0  / END OF NON CONVENTIONAL SOURCE FAULT CONTRIBUTION DATA
Q